Canine Pro-amylin ELISA

Canine Pro-amylin ELISA

Canine Pro-amylin ELISA

  • No.£ºml-1013913
  • Product Size£º96 Tests
  • Price:$699
  • Marking£º comment rank 5
  • Price     Ask for directions Tel£º4008-898-798 / 021-61725725

Datasheet

FAQs

Relevant

Product Name

Canine Pro-amylin ELISA

Species

Canine

Product Size

96 Tests

Concentration

 

Sensitivity

 

Principle

Competitive ELISA

Sample Volume

100 ul 

Assay Time

90 minutes

Platform

Microplate Reader

Conjugate

HRP

Detection Method

Colorimetric

Storage

2-8°C

 

1.    Do I have to run all of my standards and samples in duplicate?

Yes, the duplicates are run in order to monitor assay precision and increase confidence in the assay results obtained.

2.    Do I have to run all of my samples at one time?

No, each kit uses stripwell microplate. This allows the user to analyse different numbers of samples at different times.

3.    What types of reproducible results are obtained with the assays?

Each kit comes with a manual containing a graph of typical data obtained. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

4.    Is it possible to store the reagents other than indicated?

Storage of the kit components under conditions other than indicated is not recommended in order to assure proper performance of the test.

5.    How should I store my samples?

Samples should be stored at -20oC or lower temperature. For long-term storage, it is recommended to freeze them at -70oC -80oC.

6.    Can I modify the protocol?

BG ELISA kits have been optimized to provide the best possible results. Modifying the format or protocol may give inaccurate and wrong results.

7.    Can I use a sample type that is not recommended in the kit insert?

The kit has been validated for the sample types listed in the kit insert. Sample types other than those validated have not been tested. Contact Technical Service for further information.

8.    My samples generated values that were outside the dynamic range of the assay. Can I use these values?

It is recommended that only sample values that fall within the range of the standard curve be used. Values outside the range of the standard curve are generally non-linear, which can lead to incorrectly extrapolated values. Samples that generate values higher than the highest standard should be (further) diluted and the assay repeated. If samples fall below the range of the assay, the sample is considered to be non-detectable.

9.    Do I have to run a Blank or Zero Standards every time?

Yes, these are required for the calculations, and reflect any subtle but significant performance changes from day to day and assay to assay. They are also extremely helpful when troubleshooting the source of a particular assay problem.

10.  Can I alter the volume of sample I use in the assay?

It is not recommended that you alter the volumes since all BG kits are designed for optimal performance at the given volumes

11.  Can components from different kits be used?

Each kit contains components which have specific lot numbers to ensure that all of the components are performing optimally alone, as well as with all of the other components in the kit. QC testing is performed on these specific lots. It is never recommended to use your own components or components from other kits or vendors.

12.  My standard curve looked fine, but I didn¡¯t get a signal in my sample when I expected to, why?

The sample may not contain the analyte. A matrix effect may be masking the detection. Ensure that the recommended dilution was followed as stated in the kit insert. If dilution was recommended, check to be sure that the dilution was performed properly. Over-dilution may cause the sample to fall below the range of the standard curve.

13.  How do you recommend I wash my plate?

If you are using an automated plate washer we recommend that the calibration be checked on a regular basis, and that the system is flushed with the Plate Washing Buffer prior to washing. The same is true for a manual washer. A repeater or a wash bottle can also be used. The user should be careful to ensure that all of the contents are aspirated and the plate tapped dry on lint-free paper.

14.  Do I need to use a plate shaker?

Reliable results can be obtained without a plate shaker, but the O.D.'s will generally be lower than those obtained using a plate shaker.

15.  Why do I have to use wavelength correction between 450-570nm?

For the ELISA assay, reading at dual wavelengths is done to correct for the optical density contributed by the plastic well, the lamp and optical fluctuations.

16.  If I extract my sample, do I still need to follow the recommended dilutions given in the kit insert?

The amount of sample dilution needed after an extraction procedure will be affected by the effects of purification and concentration in the protocol used. The amount of dilution or concentration will have to be determined by the end-user.

17.  What is the expected concentration of analyte that I should expect to find?

The amount of a given analyte may vary not only from species-to-species, but also between tissue and cellular sources. The best source of this information is the current literature that is easily accessed through the Internet at multiple scientific databases.

18.  My optical densities were a little higher (or lower) than those in the manual that came with my kit. Why?

The optical density is affected by a number of physical conditions such as time and temperature. We suggest that you shorten or lengthen the final incubation with substrate solution to compensate.

19.  What are the reasons for High Background?

1)     Improper Washing: Check volume of washing buffer reservoir and make sure all recommended washing steps are performed.

2)     Contaminated Substrate: Make sure there is no contamination of the substrate with metal ions or oxidizing reagents, before use. Keep the extra substrate solution separately during the ELISA substrate development time.

3)     Substrate exposed to light: Exposure to light may result in a blue color of the substrate. Keep solutions in the dark (vial) until ready to dispense into the plate.

4)     Wrong Incubation Times/Temperatures: Generally follow the test protocol regarding incubation times and temperatures. However, if all wells are intensely and equally colored with no intensity gradient observed in the standard dilution series, then it may be necessary to observe the substrate reaction as the color is developing, in order to stop the reaction sooner.

 

 

Promise
  • Quality assurance£ºPseudo label,help you distinguish between true and false.
  • Delivery guarantee
    Spot Products£¬On-time delivery¡£
  • After-sale service
    Test questions£¬Technical support¡£
Contact us

Shanghai Enzyme-linked Biotechnology Co., Ltd.
Order Hotline£º4008-898-798 / 021-61725725
Fax£º021-57688126
Address£ºShanghai City, Minhang District Yuanjiang Road No. 5500

Official WeChat
WeChat scan two-dimensional code, Madden offers accessible!

Shanghai Enzyme-linked Biotechnology Co., Ltd. rss© 2008-2014 ICP 12045995
Imported ELISA Kit | Human ELISA Kit | Mouse ELISA Kit | Rat ELISA Kit